A survey on improving validation in plasma samples by niraparib and LC-MS/MS methods

Ravishankar (1) , Ramya (2) , Jaffar Hussain (3) , Virendra Kumar (4)
(1) Department of Psychiatry, Konaseema Institute of Medical Sciences Research Foundation, Amalapuram, Andhra Pradesh, India, India ,
(2) Department of OBG, Konaseema Institute of Medical Sciences Research Foundation, Amalapuram, Andhra Pradesh, India, India ,
(3) Department of Forensic Medicine, Meenakshi Academy of Higher Education and Research, Chennai, Tamil Nadu, India, India ,
(4) Department of Forensic Medicine, Meenakshi Academy of Higher Education and Research, Chennai, Tamil Nadu, India, India

Abstract

The objective of an exit survey is to improve and authorize a rapid and efficient “liquid chromatography-tandem mass spectrometry (LC-MS/MS)” technique for examination of Niraparib in plasma samples. Niraparib was separated utilizing “X-Bridge C18, 50 x 4.6 mm”, 5 µm column with MP composed of 10 mM Methanol & Ammonium format in a proportion of (20:80 v/v). MRM positive mode is utilized to identify the Niraparib at 321.5®195.4. The approach illustrates sinter & intraday precision surrounded by0.7 to 2.0 and 0.7 to 2.7 % and accuracy within 101.4-102.4 & 99.5-104.8 %. Germline mutations in BRCA1 and 2, two genes associated with mechanisms of DNA reparation impairment, are appeared to be connected with breast incidence and malignant ovarian growth, both irregular & familiar. PARP is a group of enzymes engaged with BER system. The presentation of PARP inhibitors in patients with BRCA-transformed ovarian malignant growth is associated with the synthetic lethality concept. Niraparib (NR) is an inhibitor of ”poly (ADP- ribose) polymerase (PARP) enzymes”, PARP-1, and PARP-2 performs a character in DNA restoration. We observed such vast numbers of challenges with the revealed strategies regarding stability & reproducibility for long-run analysis. It is crucial to building up the tremendous bioanalytical method with appropriate Deuterated or analog-based internal standard in terms of reproducibility and matrix effect.

Full text article

Generated from XML file

Authors

Ravishankar
Ravishankar@gmail.com (Primary Contact)
Ramya
Jaffar Hussain
Virendra Kumar
Ravishankar, Ramya, Jaffar Hussain, & Virendra Kumar. (2020). A survey on improving validation in plasma samples by niraparib and LC-MS/MS methods. International Journal of Research in Pharmaceutical Sciences, 11((SPL 4), 276–281. Retrieved from https://ijrps.com/home/article/view/1539

Article Details

No Related Submission Found