High Response Bio-Analytical Validation approach of Nadolol and Bendroflumethiazide by LC-MS/MS on Rat plasma

Naveen V M K (1) , Veeraswami B (2) , Srinivasa Rao G (3)
(1) Department of Chemistry, GITAM Institute of Science, GITAM Deemed to be University, Visakhapatnam-45, Andhra Pradesh, India, India ,
(2) Department of Chemistry, GITAM Institute of Science, GITAM Deemed to be University, Visakhapatnam-45, Andhra Pradesh, India, India ,
(3) Department of Chemistry, GITAM Institute of Science, GITAM Deemed to be University, Visakhapatnam-45, Andhra Pradesh, I, India

Abstract

A very strong responsive and straight forward the LC-MS / MS assay was developed to and witnessed for that gradation in Nadolol and Bendroflumethiazide in rat plasma. The chromatographic conditions involve isocratic mode using Waters symmetry C18 (150x4.6 mm, 3.5 microns) column. A 0.1 per cent Smartphone process OPA (orthophosphoric Acid) Acetonitrile and in 60:40 is employed, and therefore the detection was administered during +ve mode of electrospray ionisation by using MS. The valid method had validated in the linear range of 8-160 ng/ml Nadolol and 1-20 ng/ml bendroflumethiazide, the precise values considered to be intraday and interday within the acceptable limit. Here these drugs are extracted from the rat plasma by using the liquid-liquid extraction. And these drugs are found stable. Through freeze Thaw, sampler app, vehicle sampler and top of the bench for the future studies. Form of liquid chromatography-tandem mass spectrometry and checked in compliance with guidelines for quantification of food and drug administration Nadolol and Bendroflumethiazide plasma in rats using D6-Nadolol and D6- Bendroflumethiazide as internal standards utilising LC-MS incorporated with quadrupole spectrometer by using electrospray ionisation technique. The target of this analysis is to be done work out the appropriateness of this approach to Nadolol and Bendroflumethiazide Applying Nadolol and bendroflumethiazide and their internal requirements at various quantification stages and retaining different parameters such as instrument durability, precision and accuracy, sample preparation techniques, instrument synchronisation, recovery and matrix effect.

Full text article

Generated from XML file

Authors

Naveen V M K
Veeraswami B
veeraswamiboddu@gmail.com (Primary Contact)
Srinivasa Rao G
Naveen V M K, Veeraswami B, & Srinivasa Rao G. (2020). High Response Bio-Analytical Validation approach of Nadolol and Bendroflumethiazide by LC-MS/MS on Rat plasma. International Journal of Research in Pharmaceutical Sciences, 11((SPL 4), 2272–2279. Retrieved from https://ijrps.com/home/article/view/2453

Article Details

No Related Submission Found