Method Development and Validation of Fludrocortisone Acetate Tablets by Reverse Phase HPLC Method

Vijey Aanandhi M (1) , Elancheziyan K (2) , Yamini R (3) , Prakash Chand T (4) , Aysha Jadeera K A (5) , Binoy Varghese Cheriyan (6)
(1) Department of Pharmaceutical Chemistry and Analysis, School of Pharmaceutical Sciences, Vels Institute of Sciences, Technology and Advanced Studies (VISTAS) Pallavaram, Chennai-600117, Tamil Nadu, India, India ,
(2) Department of Pharmaceutical Chemistry and Analysis, School of Pharmaceutical Sciences, Vels Institute of Sciences, Technology and Advanced Studies (VISTAS) Pallavaram, Chennai-600117, Tamil Nadu, India, India ,
(3) Department of Pharmaceutical Chemistry and Analysis, School of Pharmaceutical Sciences, Vels Institute of Sciences, Technology and Advanced Studies (VISTAS) Pallavaram, Chennai-600117, Tamil Nadu, India, India ,
(4) Department of Pharmaceutical Chemistry and Analysis, School of Pharmaceutical Sciences, Vels Institute of Sciences, Technology and Advanced Studies (VISTAS) Pallavaram, Chennai-600117, Tamil Nadu, India, India ,
(5) Department of Pharmaceutical Chemistry and Analysis, School of Pharmaceutical Sciences, Vels Institute of Sciences, Technology and Advanced Studies (VISTAS) Pallavaram, Chennai-600117, Tamil Nadu, India, India ,
(6) Department of Pharmaceutical Chemistry and Analysis, School of Pharmaceutical Sciences, Vels Institute of Sciences, Technology and Advanced Studies (VISTAS) Pallavaram, Chennai-600117, Tamil Nadu, India, India

Abstract

The purpose or intent of this current study was to establish a fast and sensitive HPLC technique for the perseverance of Fludrocortisone acetate and utilizing best frequently used HPLC technique. This method had been validated as per the ICH requirements to assure that the method consistently meets the predetermined specifications and quality attributes.Utilizing filtered and degassed pH 3.0 Phosphate buffer and Acetonitrile in the ratio 90:10 as a Mobile phase-A and pH 3.0 Phosphate buffer and Acetonitrile in the ratio 65:35 as a Mobile phase-B the established RP-HPLC technique was done. The separation was achieved by using Waters, X-Bridge Shield RP18, (150 X 4.6-mm), 3.5-µm column. Run time and Flow rate was set 45minutes and 1.2mL/min. Injection volume 100µL and wavelength was set 240nm.The correlation coefficient square for fludrocortisones acetate and Fludrocortisone Impurity was found to be 0.9991 and 0.99997. The SD and %RSD for Fludrocortisone Impurity was found to be 0.02 and 1.48 represents method precision. Following validated parameters lies within the limit. Hence, the developed method was precise, simple, fast and accurate.

Full text article

Generated from XML file

Authors

Vijey Aanandhi M
hodpchemistry@velsuniv.ac.in (Primary Contact)
Elancheziyan K
Yamini R
Prakash Chand T
Aysha Jadeera K A
Binoy Varghese Cheriyan
Vijey Aanandhi M, Elancheziyan K, Yamini R, Prakash Chand T, Aysha Jadeera K A, & Binoy Varghese Cheriyan. (2020). Method Development and Validation of Fludrocortisone Acetate Tablets by Reverse Phase HPLC Method. International Journal of Research in Pharmaceutical Sciences, 11(4), 6826–6833. Retrieved from https://ijrps.com/home/article/view/1761

Article Details

Most read articles by the same author(s)

1 2 > >> 
No Related Submission Found