Perimeter of The Tricuspid Valve: A Cadaveric Human Heart Study

Kirti Chaudhary (1) , Amey Dhatrak (2) , Brij Raj Singh (3) , Ujwal Gajbe (4)
(1) Department of Anatomy, Jawaharlal Nehru Medical College (Datta Meghe Institute of Medical Sciences) Sawangi Wardha-442004, Maharashtra, India, India ,
(2) Department of Community Medicine, MGIMS, Sevagram- 442102, Wardha, Maharashtra, India, India ,
(3) Department of Anatomy, Datta Meghe Medical College, Hingna, Nagpur, Shalinitai Meghe Hospital and Research Centre (Datta Meghe Institute of Medical Sciences), Hingana, Nagpur-441110, Maharashtra, India, India ,
(4) Department of Anatomy, Datta Meghe Medical College, Hingna, Nagpur, Shalinitai Meghe Hospital and Research Centre (Datta Meghe Institute of Medical Sciences), Hingana, Nagpur-441110, Maharashtra, India, India

Abstract

Historically, the research on the right ventricle (RV) has been neglected by his left equivalent because of the complexity of left ventricle (LV) dysfunction. Tricuspid regurgitation (TR) can be classified as linked to primary valve disease or functional in nature, but most are functional. Although it was historically assumed that such functional Tricuspid regurgitation, i.e. arising from left- sided disease, and it can be resolved after corrective surgery, but after successful surgery, on the aortic or mitral valve annular dilatation, the Tricuspid regurgitation and right ventricular dysfunction may persist.To study the circumference of tricuspid orifice and it’s the diameter in two perpendicular planes and its comparison among the male and female population. The material for the present study comprised of 50 formalin fixed human hearts (35 males and 15 females) which were obtained from the department of anatomy. In this study, it is observed that: The mean value of circumference of a tricuspid orifice is 11.01+/-0.63 cm. The diameter of tricuspid orifice along  the frontal dimension is 3.06+/-0.38 cm, and the diameter along the sagittal dimension is 2.26+/-0.23 cm. The measurements of the circumference of tricuspid orifice reported for males and females in western countries were higher than the present study and the diameter along the frontal dimension is greater than the diameter along the sagittal dimension. The tricuspid valve diameter along the frontal dimension was more than the diameter along the sagittal dimension in both males and females.

Full text article

Generated from XML file

Authors

Kirti Chaudhary
Amey Dhatrak
Brij Raj Singh
drbrijsingh@gmail.com (Primary Contact)
Ujwal Gajbe
Kirti Chaudhary, Amey Dhatrak, Brij Raj Singh, & Ujwal Gajbe. (2020). Perimeter of The Tricuspid Valve: A Cadaveric Human Heart Study. International Journal of Research in Pharmaceutical Sciences, 11(3), 3424–3428. Retrieved from https://ijrps.com/home/article/view/726

Article Details

No Related Submission Found