Development and validation of stability indicating HPLC method for the estimation of 5-Fluorouracil and related substances in topical formulation

Sriguru Bandana (1) , Nandha NP (2) , Vairale AS (3) , Sherikar AV (4) , Nalamothu V (5)
(1) Department of Dermatology, Analytical Research & Development, Dr.Reddy’s Laboratories, IPDO, Bachupally, Hyderabad- 500 072, India, India ,
(2) Department of Pharmacy & Biomedical Sciences, College of Pharmacy, University of South Carolina, Columbia, USA, United States ,
(3) Department of Dermatology, Analytical Research & Development, Dr.Reddy’s Laboratories, IPDO, Bachupally, Hyderabad- 500 072, India, India ,
(4) Department of Dermatology, Analytical Research & Development, Dr.Reddy’s Laboratories, IPDO, Bachupally, Hyderabad- 500 072, India, India ,
(5) Department of Dermatology, Analytical Research & Development, Dr.Reddy’s Laboratories, IPDO, Bachupally, Hyderabad- 500 072, India, India

Abstract

A sensitive HPLC method has been developed and validated for the determination of 5-Fluorouracil (5-FU) and related substances in a novel topical formulation. The highly polar molecule requires aqueous mobile phase for the elution and separation of 5-Fluorouracil and its impurities (Impurity A, B and C official in EP). The developed method is found to be specific, reproducible, and stability indicating. The Phenomenex Synergi Polar RP 250×4.6mm 4μ column was used and mobile phase consisted of 0.1M potassium di hydrogen phosphate (KH2PO4) buffer to achieve good resolution and retention of the analyte and its impurities. The detector linearity was estab-lished from concentrations ranging from 0.01 μg/ml to 500 μg/ml for 5-Flurouracil and from 0.01 μg/ml to 0.08 μg/ml for related substances with a correlation co-efficient of 0.999. The relative response factor (RRF) values of impurity A, impurity B and impurity C determined from linearity plots were 1.9, 0.9 and 1.4 respectively. The limit of detection (LOD) and limit of quantification (LOQ) found to be in a range of 0.004 μg/ml and 0.014μg/ml for 5-Fluorouracil and related substances respectively. The molecule was stable in all the stress conditions such as acid, base, oxidation, heat and photolysis as per the recommendations of ICH guidelines. The method was proved to be robust with respect to changes in flow rate, pH and column temperature. The proposed method is found to be sensitive, precise, rapid, reproducible, and offers good column life.

Full text article

Generated from XML file

Authors

Sriguru Bandana
srigurub@drreddys.com (Primary Contact)
Nandha NP
Vairale AS
Sherikar AV
Nalamothu V
Sriguru Bandana, Nandha NP, Vairale AS, Sherikar AV, & Nalamothu V. (2010). Development and validation of stability indicating HPLC method for the estimation of 5-Fluorouracil and related substances in topical formulation. International Journal of Research in Pharmaceutical Sciences, 1(2), 78–85. Retrieved from https://ijrps.com/home/article/view/2853